What are the problems with the dust removal framework in practical applications?(1)

Uniform airflow distribution: airflow in the electric field will have a major impact on the rate of dust removal from the filter chamber, but most of them can only be judged by experience. The dust removal frame can adjust the baffle in a cold state so that the airflow is evenly distributed. The multichannel electrostatic precipitator and the vertical electrostatic precipitator can be judged from other aspects.

The crown cable is broken: the crown cable of the electrostatic precipitator is mainly caused by the equipment’s skills and the quality of the cable. The quality of the line must be verified in the selection of the location, the favorable terrain, and the choice of materials. In practice, improved device management is also very important. The small frame of the device must be torn and welded, and the dust frame must be corrected one by one so that the frame does not deform. Dissatisfaction must be controlled within the limits of the norm. When positioning, compare the balance of force between adjacent lines. It is advisable to break the cable during spot welding, and it is not advisable to weld the cable to the small frame. Experience shows that there is less chance of cable breakage when the dust removal frame nut is not welded than if it is welded, so it should be remembered during installation. For example, a cement plant has paid attention to the installation and management of crown cable, so that the electrostatic tail precipitator has used angular steel barbed wire for two years without disconnection, and the dust removal equipment has always been safe and in operation.